1. Basic Application
R
Heating
Cooling
Mixing
2. Capacity
E/O
Cv Rating_______________________________________________
GPM or #/hr. ____________________________________________
2a. Pipe Size____________________________________________
2b. Trim Material
Bronze
Stainless
2c. Packing Material
EP V-Ring
Teflon V-Ring
3. Process Load
E/O
Flow (GPM) of material to be
heated, cooled, or mixed ______________________________
•Temperature increase or decrease
of material ___________________________________________
4. Media Through Valve
Steam
Inlet pressure
R
________________________________________
Pressure Drop (P)
N
___________________________________
Water
Inlet pressure
R
________________________________________
Pressure Drop (P)
N
___________________________________
Temperature
R
_________________________________________
Other
Material Flowing Through Valve _________________________
Inlet Pressure
R
________________________________________
Pressure Drop (P)
N
___________________________________
Temperature
R
_________________________________________
5. Media At Sensor (Bulb)
R
Type
Water
Chemical (Specify) _________________________________
Temperature
Desired Control Point _______________________________
Maximum Temperature Exposure ____________________
Optional Temperature Indicator (Gauge)
6. Bulb and Capillary Characteristics
R
Material
Copper
316 Stainless
7. Process Connection, Optional Bulb Well,
Capillary Length
Process Connection
Standard Fixed Union with NPT Connection (Style D)
Special Adjustable Union with NPT Connection (Style JD)
Special Vertical Fixed Union with NPT Connection (Style V)
Plain Bulb [No fittings] (Style J)
Optional Bulb Well
Copper
Stainless
Capillary Length
8(Standard)
15(Standard)
30(Optional)
8. Part #_______________________________________________
NOTES
R
Required Information
E/O
Either/Or Information
If the required flow rate through the valve (Capacity, Item #2) is
not known, it can be calculated from the Process Load
Information (Item #3).
N
Nice To Have Information
Pressure drops across the valve can be assumed if they are not
specified by the customer.
#11 Regulator
Single Seat (CD)
shown
Media Through Valve
Media
at Sensor
(Bulb)
Process
Load
Capillary
Process
Connection
Selecting the correct model regulator for the specific application is extremely important to maintaining a smooth-running
process. To get the regulator that will best meet your needs, please be sure to answer every question noted as “Required”
on this Application Data Sheet.
Sample Application
© November 2002 Powers, a Watts Industries Co.
USA Office Phone: 800.669.5430
Canada Office Phone: 888.208.8927
www.powerscontrols.com
Regulator
Application Data Sheet
Form ADS#11FW
No. 11
Page 1 of 2
ADS#11FW 0247 Printed in U.S.A.
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Application Data Sheet

1. Basic ApplicationR Heating Cooling Mixing2. CapacityE/OCv Rating_______________________________________________GPM or #/hr. __________________

Page 2 - Flowrite

1. Valve StyleR Normally Open (air to close) Double Acting Normally Closed (air to open) _________________ Mixing2. Valve Body MaterialRProce

Commentaires sur ces manuels

Pas de commentaire