FEATURES
Compact design can be installed in any position
Low maintenance epoxy coated aluminum manifold hous-
ing and stainless steel external parts resist corrosion
Good dynamic response, adjustable combination of pro-
portional band and air exhaust capacity
Not sensitive to mechanical vibrations
Rugged design, very easy to repair
Only one moving valve part, therefore, less sensitive to
clogging
Usable as positioner or as motion transmitter
Standard yoke mounting per IEC 534-6
APPLICATIONS
The 147-3000 Pneumatic Positioner Relay improves control
system performance by providing the following functions:
.....Elimination of valve movement caused by line pressure
variations
...............................Minimize effects of stick-slip (hysteresis)
...........................................................Faster valve movement
......................Increased close-off rating when I/Ps are used
............................................................................Split ranging
OPERATION
The 147-3000 single acting positioner assures an exact rela-
tionship between actuator valve stem position and controller
input signal. Operating on the time-proven force balance
principle, valve stem motion is transferred through a feed-
back spring which opposes the force produced by the input
signal diaphragm. Supply air is fed through a pneumatic
three-way valve which has output pressure to the diaphragm
actuator that is varied as a result of movement of the feed-
back arm. Any change in instrument signal pressure or exter-
nal actuator force will either increase or exhaust positioner
output pressure causing movement of the actuator stem until
an equilibrium is reached. Stepless combination of gain
adjustment and stroking speed control provides unusual
capability of matching valve performance with process loop
system dynamics..
TECHNICAL INSTRUCTIONS
SINGLE ACTING POSITIONING RELAY
147-3000
OPERATING
Ambient Temperature Range -10°F to 150°F (-23°C to 65°C)
Travel See Back Page
Signal Input 315, 39, 915 psi
Maximum Open Loop Gain 150:1
Minimum Open Loop Gain* 50:1
Steady State Air Consumption 9 psi signal / 20 psi supply 0.10 SCFM
Linearity <±1.3% of span
Hysteresis <0.4% of span
Dead Band <0.2% of span
Threshold Sensitivity <0.07% of span
Supply Pressure Effect 0.12% of span per psi
Ambient Temperature Effect 0.1% per 2°F
Travel Time 46 in2 Actuator @ 20 psi Supply Air In* 1.8 sec. for 1/2"
Air Out* 2.1 sec. for 1/2"
75 in2 Actuator @ 20 psi Supply Air In* 3.8 sec. for 3/4"
Air Out* 2.3 sec. for 3/4"
PHYSICAL
Air Connections 1/4" NPT Instrument and Supply
1/8" NPT Output and Gauge
Body Materials Manifold Housing Material Anodized Epoxy Coated Aluminum
Upper Housing Material High Strength Polyamide
External Feedback Parts Stainless Steel
Shipping Weight 1.2 lbs. (.544kg)
Dimensions 2-1/4" x 3-1/16" x 4-1/4"
(5.7 cm x 7.8 cm x 10.8 cm)
Supply Air Maximum of 50 PSI Maximum of 30 PSI
Pressure PSI with 46 Actuator With 75 Actuator
*@ Maximum speed setting (gain screw flush).
SPECIFICATIONS
Form TI147-POS
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - TECHNICAL INSTRUCTIONS

FEATURES• Compact design can be installed in any position• Low maintenance epoxy coated aluminum manifold hous-ing and stainless steel external parts

Page 2

TI147-POS Page 2INSTALLATIONBefore starting, make sure the positioner stroke range isappropriate for your valve. See Table 3 on back page. Mounting1.

Page 3 - 46 sq.in

TI147-POS Page 3PARTS AND ACCESSORIES LISTCLOSEDOPENN.C.46 sq.in.OPENCLOSEDN.O.46 sq.in.Air Connectionson topNote: Install take-offplate with flange u

Page 4 - Reverse Acting (NC and NO)

TI147-POS Page 4milled outwhen factory ordered75 sq. in.N.O. & N.C.Figure 3 - 75 sq. in. Valve withPositioner both Direct andReverse Acting (NC an

Page 5 - TI147-POS Page 5

TI147-POS Page 57SUPPLYSIGNAL2627 5 4 3 2 8OUTPUT1612131469101115117Table 1. Positioner Repair PartsItem # Description Part #1 Arm -2-4 Take-off P

Page 6

TI147-POS Page 6TABLE 3TABLE 4Stroke Actual Take Off Complete Sprin Kit ColorOperation Range Stroke (in) Pin Setting (in) Positioner Only Wire (Dim in

Page 8 - WARRANTY INFORMATION

TI147-POS Page 8WARRANTY INFORMATIONPowers Process Controls warrants that the equipment manufactured by it is free from defects in material and workma